Maintenance, Repair & Overhaul Case Studies
MRO / Manufacturing / Engineering Success Story
AAV Driver Display Unit (DDU) & Indicator Panel
P/N 5429429 – AAV Drivers Display Unit (DDU)
The DDU is used by the driver of the AAV to display transmission oil temperature and pressure, engine oil temperature and pressure, engine water temperature, fuel level and battery voltage. Artemis received units from the SECREP program that were in very bad shape, with cracked bar graphs, burnt CCAs, field expedient repairs on the circuit board, and fractured exteriors, and even filled with salt water. The DDUs were shipped back clean, repaired and fully functioning in 30 days.






MRO Success Story
M1A1 Digital Electronic Control Unit
We received a damaged digital electronic Control Unit (DECU) from PROS program, with very limited schematics available. The Artemis team reverse engineered schematics, designed and built a test set, simulated entire AGT-1500 gas turbine engine and designed the test procedure.
MRO / Manufacturing Success Story
3KW External Auxiliary Power Units – M1A1 Abrams
Artemis originally repaired M1 Abrams 2kW and 3kW External Auxiliary Power Units (EAPUs) for the U.S. Marine Corps as part of the SECREPS program. In 2014, Artemis acquired EAPU IP and technical data from the original manufacturer, Walker Power Systems. In 2018, EAPUs built by Artemis successfully completed functional and environmental testing required for Artemis to replace Walker Power as the source of supply for EAPUs. Since that time, Artemis has built, overhauled, and converted hundreds of EAPUs for the United States military and its allies. Artemis is currently the sole source supplier to the military and the Defense Logistics Agency (DLA) for EAPUs including spares of any EAPU downparts. Artemis has manufactured spares for the U.S. Army and Marine Corps, as well as for allied countries including Australia, Iraq, and Morocco.